Product details

Name: LXSYY-15E ~ 50E rotor photoelectric direct reading liquid sealed VRLA remote meter


Uses: This series of water meter for drinking water usage. Residents (sub-table) or industrial use.


Conditions of Use:

Temperature class: T30

Pressure Level: MAP 10 / MAP 16

Pressure loss rating: △ P 63

Indication error limit:

From minimum flow (Q1) to excluding transitional flow (Q2) of the lower zone ± 5%

From the high zone of the transitional flow (Q2) to overload flow (Q4) of ± 2%


Characteristics and main technical parameters:

Multi-streaming technology;

Horizontal mounting, measuring range R = 80

Digital counter wheel with special liquid package, long-term clear reading

Movement, using high-quality materials, long life, stable and reliable performance, external adjustment (seal); ductile iron or copper shell case (Case spray)

Direct-reading Valve Control module uses photoelectric direct reading technology to read data word round, compared with the conventional pulse table, it can be reduced to zero reading error, AMR metering system is ideal zero error product. Module uses low-power design, usually no power supply, only when the meter readings and conduct valve switch its power needs. The module can be installed directly in the base table counter, assembled into remote base table VRLA photoelectric direct reading table, with the smart metering system equipment, complete intelligent reading copy cell data and remote meter control valve on / off, and Implementation and settlement center networking data sharing.


一、Features

1, reading the word round of data, compared with the conventional pulse table, it can be reduced to zero reading error;

2, low-power design, and only if the readings valve switch supplied with power;

3, the use of advanced data encoding and verification technology, high reliability communications;

4, in line with "electronic remote meter" (CJ / T 224-2012) standard;

5, compatible with a variety of communication protocols; DL / T645, CJ / T188 and internal protocols;

6, to meet the EMC, ESD, EMI and other electronic products, electromagnetic compatibility design requirements, to achieve industry-leading level;

7, combined with the host computer system, to establish a remote automatic meter reading management system, the real meter reading, monitoring automation.


二、Second, the technical parameters

2, working voltage: DC 36V;

3, the working current:

Current meter reading ≤9.0mA

Quiescent current ≤1.3 mA

Valve On / Off Bus Current ≤50 mA (reference value, the valve will be different depending on the difference)

Valve open / close valve motor input current ≤30 mA (reference value, the valve will be different depending on the difference)

4, the working environment: temperature: -10 ℃ ~ + 45 ℃ Humidity: 0 ~ 95% RH;

5, Storage temperature: -25 ℃ ~ + 65 ℃;

6, with the host computer communication: M-bus field bus;

7, communication transmission speed: 2400 baud;

8, communication protocol: DL / T645, CJ / T 188 and an internal protocol (or user-specified statute);

9, the maximum transmission distance communication: 300m; (communication line specification AVVR2 × 0.75)

10, the bus pin ESD protection exceeding 10kV;

11, the short-circuit current protection;

12, for the bus open, short, idle fault protection.


The main technical parameters:

caliber DNmmMeasuring range Q3/Q1Traffic overload Q4Common flow Q3Transitional Flow Q2Minimum flow Q1Starting flowMinimum readingThe maximum reading
m3/hL/hm3
15803.1252.55031.25120.0000599999
1004025
1602515.6255
2002012.5
208054805016
1006440
16040256
2003220
25807.87512678.7517
100100.863
1606339.3758
20050.431.5
328012.51020012523
100160100
16010062.510
2008050
4080201632020050
100256160
16016010035
20012880
508031.2525500312.560
100400250
160250156.2540
200200125


● flow error curve


● Pressure loss curve


● Dimensions and weight

Nominal diameterlong Lwidth Bhigh HConnection thread (D)weight(kg)
(mm)mm
15165/19099104G3/4B1.5/1.6
20190/19599106G1B1.7
25260/225104120G1 1/4B2.6/2.4
32260/230104120G1 1/2B2.8/2.7
40300/245125155G2B5.4/4.5
50300125155B2 1/2B7.2
280158175Flanged Press GB4216.4.84 D=165 D1=12514




● Conditions of Use

Working temperature no higher than 40 °c

Working pressure is less than 1MPa


Ningbo Shengde WaterMeter Co.,Ltd.Reserved.code

Adderss:Xin'an lndustry Zone, Xijiao, Ningbo, China Tel:+86-0574-88440229 Sales dep tel:

Contact person: Purchasing dep tel: E-mail:[email protected] Zip:315101

Copyright ? Sunway Hanguang Electric Manufacturing Limited

主站蜘蛛池模板: 91香蕉ios下载 | 国产精品国产三级国产AV主播 | 国产裸体美女在线观看 | 国产乱码一区二区三区爽爽爽女仆 | 国产羞羞黄色视频网站在线 | 国产精品国产成人 | 日韩一级A级 | 99热在线都是精品 | 国产精品无圣 | 国产一区二区三区乱 | 亚洲欧美国产另类首页 | 日韩在线永久免费播 | 男人AV资源 | 精品国产午夜福利在线观看 | 国产女人成人精品视频 | 91最新人成在线观看 | 三级片在线免费观看 | 国产精品大战 | 欧美日韩精品一区二区三区四区 | 麻豆国产av巨作国产剧情 | 欧美日韩综合一级亚洲 | 变态另类天堂无码专区 | 国产女人高潮视频在线观看 | 成人五月激情在线视频 | 亚洲福利B在线 | 国产永久一区二区三区 | 加勒比东京热无码中文字幕 | 亚洲国产精品视频一区 | 尤物网址在 | 亚洲成人一区在线 | 亚洲欧美日本韩国在线观看 | 在线看片射挤奶 | 亚洲AV图片在线观看 | 中文字幕免 | 日韩亚洲欧美最大 | 久久精品国产亚洲AV麻豆色欲 | 亚洲毛片一区二区三区 | 日韩欧美福利 | 丁香五香天堂网 | 国产日韩欧美日韩欧美 | 亚洲熟妇乱伦 |